BUILDER OR. This MARCO fireplace and components are safe when installed 2 Feb 2011 pdf guides.
Marco Gas Fireplace Instructions Manual And TheFind the user manual and the help you need for the products you own at ManualsOnline.
Marco 41 Fireplace Install and operating guide - models 792861B, 792862B, 792863B, and 792864B. Asked by Jeff on Get free help, tips amp; support from top experts on marco 792862b related issues. User manuals, Marco Indoor fireplace Operating guides and Service manuals. Looking for some insight as to why a Marco Fireplace (mn 792863B) that states intended for use with solid wood fuel only on its nameplate, N25discuss72157686733020690. The next was something similar to This fireplace is approved for use with solid fuel or for use with a vented gas log approved to ANS Z21.60, Z21.84. Then there was This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA 2-72 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. All of which may be followed by the warnings below. Similar Threads: Outdoor fireplace Prefab Fireplace Clearances Gas Fireplace Chimney Clearance Wood Burning Fireplace Fireplace Had Its Own Air Handler Unit. I am presuming that say something like this: (filling in the blanks with the underlined all caps) Fireplace intended for use with S olid wood fuel only. See Marco MFG installation and OP erating instructions for this WHEN USING GAS F uel. That would indicate that, yes, this fireplace can be used with gas logs provided the installation is installed and used in accordance with the requirements of the installation instructions. I search the internet also and could not find the installation instructions. I would report what you observed and recommend the fireplace be inspected by a Certified F.I.R.E inspector. They will be able to clear up any misunderstandings and incorrect installations (or advise removalreplacement if needed). That is like calling for a contractor for repairs - you inspected it, you found this stuff not quite right, you recommend an expert to make necessary corrections and repairs as needed. If they confirm that there is nothing wrong with the installation, your client got their moneys worth, if the confirm that is incorrect, or find other things which are incorrect, your client got their moneys worth. So it says See MARCO MFG Installation and Operating Instructions for this Model. Nothing in it referencing the potential use of a gas appliance. Thus leaving me with my original quandry.the reference to use with a gas appliance: when using gas. Obviously, before reporting anything Im trying to gain enough information to better understand what I observed (or didnt observe), and to potentially save my client further expense by being able to make an intelligent and accurate reporting of my findings. When I cant, or if I can determine its incorrect or unsafe, Ill punt. Brian - off message: Im selecting Instant email notification but not getting the notification. I used to, and I do get the regular digest updates from InspectionNews.net). That label, as I see it (barring another mistake on the gas part) indicates the fireplace is Intended for use with solid wood fuel only. IF that is the case, then that fireplace is NOT being used as it was tested, listed, and labeled for. The first factory-built fireplace systems were approved for solid fuel and DID NOT have any means to install a gas line through the side wall of the firebox. Some individuals decided to punch holes through the metal voiding the listing and posing a fire hazard. The manufacturers then supplied listed means to install the gas lines for the log lighter ONLY. This application is detectible by the physical design of the side wall (sometimes bottom) refractory. Marco Gas Fireplace Instructions Series Of FireplacesThe next series of fireplaces have different statements on the manufacturers labels due to changes within the testing standards. The first was something similar to the following, for use with solid fuel only and approved decorative gas appliances. The next was something similar to for use with solid fuel only or listed decorative gas appliances. Then there was This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA 2-72 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. All of which may be followed by the warnings below.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |